General Description and Specifications
1-16 Quantum DLT 8000 Tape System
Table 1−15 Radiated Emissions
NOTE
Table 1-15 shows the Class B equipment limits for radiated interference field
strength in the frequency range from 30 MHz to 30 GHz at a test distance of 3 and
10 meters.
Frequency Range (MHz) Quasi-Peak Limit dB (µV/m
@ 3 Meters @ 10 Meters
30 to 230 40 30
230 to 1000 46 37
Above 1000 54 N/A
Table 1−16 Magnetic Radiated Susceptibility
Low Frequency, Magnetic Fields, 10 to 3000 kHz
100 dB (pt) @ 10 kHz
Declining to 80 dB (pt) @
1 MHz
No errors, no screen distortion
Table 1−17 Radiated Susceptibility
High Frequency, Electric Fields, 1 to 1000 MHz
3 V/m (rms) 80% modulated
1 kHz
No errors, no screen distortion
S/W recoverable errors
No hardware failure