General Description and Specifications
1-6 Quantum DLT 8000 Tape System
1.3.6 Temperature and Humidity
Table 14 provides the temperature and humidity specifications for the tape system.
Table 14 Temperature and Humidity Specifications
Description Integratible Version Tabletop Version
Operating Ranges
Temperature Range 50°F to 104°F (10°C to 40°C) 50°F to 104°F (10°C to 40°C)
Temperature Gradient 18°F (10°C ) per hour (across
the range)
18°F (10°C ) per hour (across
the range)
Dry Bulb Temp. Range 50°F to 104°F (10°C to 40°C) 50°F to 104°F (10°C to 40°C)
Wet Bulb Temperature 77°F (25°C) 77°F (25°C)
Relative Humidity 20% to 80%, non-condensing 20% to 80%, non-condensing
Humidity Gradient 10% / hour 10% / hour
Storage Ranges (Unpacked or Packed)
Temperature Gradient 36°F (20°C ) per hour with 5°
margin (across the range)
36°F (20°C ) per hour with 5°
margin (across the range)
Dry Bulb Temp. Range -40°F to 150.8°F (-40°C to
66°C)
-40°F to 150.8°F (-40°C to
66°C)
Wet Bulb Temperature 114.8°F (46°C) 114.8°F (46°C)
Relative Humidity 5% to 95%, non-condensing 5% to 95%, non-condensing
Humidity Gradient 10% / hour 10% / hour
Shipping Ranges
Temperature Gradient 36°F (20°C ) per hour with 5°
margin (across the range)
36°F (20°C ) per hour with 5°
margin (across the range)
Dry Bulb Temp. Range -40°F to 150.8°F (-40°C to
66°C)
-40°F to 150.8°F (-40°C to
66°C)
Wet Bulb Temperature 114.8°F (46°C) 114.8°F (46°C)
Relative Humidity 10% to 95%, non-condensing 10% to 95%, non-condensing
Humidity Gradient 10% / hour 10% / hour