Quantum DLT 8000 Manual Página 342

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 341
SCSI Commands
5-198 Quantum DLT 8000 Tape System
REQUEST SENSE Command (03h) (continued)
Table 589 Supported ASC / ASCQ in Hex (continued)
Sense Key ASC ASCQ Meaning
05h ILLEGAL REQUEST
(cont.)
3B 0D Media Destination Element Full
3B 0E Media Source Element Empty
3D 00 Invalid Bits in ID Message
53 02 Media Removal Prevented
82 00 Not Allowed if Not at BOT
06h UNIT ATTENTION 28 00 Not Ready To Ready Transition
29 00 Generic Reset Occurred – Cause Undetermined
29 01 Power On Occurred
29 02 SCSI Bus Reset Occurred
29 03 Bus Device Reset Occurred
29 04 Device Internal Reset
2A 01 Mode Parameters Changed
2A 02 Log Parameters Changed
3F 01 Microcode Has Been Changed
5B 01 Log Threshold Condition Met
07h DATA PROTECTED 27 80 Hardware WRITE Protect
27 82 Data Safety WRITE Protect
08h BLANK CHECK 00 05 EOD Encountered
09h VENDOR UNIQUE XX * YY * Code Update Event
* Where XX = Drive Revision Code and YY = Controller Revision Code
(continued)