Quantum DLT 8000 Manual Página 240

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 239
SCSI Commands
5-96 Quantum DLT 8000 Tape System
MODE SELECT Command (6) / (10) (15h) / (55h) (continued)
5.9.9 EEPROM VENDOR UNIQUE PAGE (3Eh)
The drive supports a vendor unique page that enables a user to modify savable
parameters. Only one savable parameter may be changed per Mode Select command.
Bit
Byte
7 6 5 4 3 2 1 0
0 PS Rsv’d Page Code (3Eh)
1 Additional Page Length
2 ASCII String of Parameter Name and Value
Figure 5–48 EEPROM Vendor Unique Page — Data Format
The ASCII string has a parameter name, followed by one or more space characters, a
parameter value, and an ASCII line feed or null character. When the string is parsed, the
parameter value is interpreted as shown in the following table. Note that the parameter name
may be in upper or lower case. The savable parameters are saved over resets and power cycles.