SCSI Commands
5-104 Quantum DLT 8000 Tape System
MODE SELECT Command (6) / (10) (15h) / (55h) (continued)
5.9.10 Changeable Parameters within MODE SELECT
The table below lists the MODE SELECT command’s changeable parameters and their
default, minimum, and maximum values. Descriptions of the various parameters are
provided in the discussions of the different mode pages within MODE SELECT. Note
that parameter rounding is supported for all parameters except for the block descriptor
length.
Table 5–48 Changeable Mode Parameters within MODE SELECT
Page: Parameter Default Minimum Maximum
Header: Buffered Mode, Device Specific Byte 1 0 1
Header: Speed, Device Specific Byte 0 0 3
Block Descriptor Length 08h 00h 08h
Block Descriptor: Block Length
10.0 GB and 20.0 GB Mode
20.0 GB and 40.0 GB Mode
35.0 GB and 70.0 GB Mode
40.0 GB and 80.0 GB Mode
0
0
0
0
0
0
0
0
FFFFFEh
FFFFFEh
FFFFFEh
FFFFFEh
READ / WRITE Error Recovery (01h): PER bit 0 0 1
Control Mode (0Ah): RLEC 0 0 1
Data Compression (0Fh): DCE 1 0 1
Disconnect / Reconnect (02h): Maximum Burst Size 0080h 0000h FFFFh
Disconnect / Reconnect (02h): DTDC 0 0 3
Device Configuration (10h): WRITE Delay Time C8h Fh 1964h
Device Configuration (10h): SEW 1 0 1
Device Configuration (10h): Select Data Compression
Algorithm
1 0 1
Comentários a estes Manuais