JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-23
ERRORS REPORTED OVER THE SCSI BUS
10h 1Ah 00h 5h A 4 Parameter length error. The parameter
list length was not valid. This error is a
result of any of the following:
Parameter List Length error in the
MODE SELECT CDB.
Illegal transfer length in CDB.
10h 20h 00h 5h A 4 Invalid Command OP code. The
operation code (OP code) for the CDB
was invalid.
10h 21h 01h 5h A, O 4 Invalid element address. There was an
invalid element address specified in the
CDB.
10h 24h 00h 5h A 4 Invalid field in CDB. There were invalid
fields in the CDB.
10h 25h 00h 5h A, O 4 Logical Unit not supported. The logical
unit number specified in the Identify
message or in the CDB is not zero.
10h 26h 00h 5h A, O 4 Invalid field in parameter list. There was
an invalid field in the parameter list.
10h 26h 02h 5h A, O 4, 15 Parameter value invalid. There was an
invalid parameter value in the parameter
list.
12h 04h 01h 02h O, B,
A, S
11 Logical Unit becoming ready.The library
is not ready, but is in process of becoming
ready.
12h 04h 12h 02h S, O 8 Library has been placed offline by system.
12h 04h 83h 02h O 11 Not Ready. Door open. The cartridge
access port door is open.
12h 87h 25h 4h I 8, 13, 12 Drive not ready. The tape drive did not
return Ready status after a reset.
Table A-4 REQUEST SENSE error information (FSC, ASC, ASCQ, and SK (continued)
FSC
ASC
(byte 12)
ASCQ
(byte 13)
Sense
Key
Cause ERP SCSI Error Message and Description