JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-5
ERROR MESSAGES DISPLAYED ON THE LCD
Failed Sequential mode action
failed.
1. Enable Sequential mode. See “Setting the
Operation Mode” on page 3-1.
2. Retry the operation.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
File Close Fail The library could not close
the USB file.
1. Ensure that the USB device is securely
inserted and retry the operation.
2. Re-write the file to the USB device and retry
the operation.
3. Retry with another USB device.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
File Create Fail The library could not create
a new file on the USB
device.
1. Ensure that the USB device is securely
inserted and retry the operation.
2. Re-write the file to the USB device and retry
the operation.
3. Retry with another USB device.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
File First Fail The library could not find
the first file in the USB
directory.
1. Ensure that the USB device is securely
inserted and retry the operation.
2. Re-write the directory to the USB device and
retry the operation.
3. Retry with another USB device.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
File Flush Fail The library could not flush
data written to the USB
device.
1. Ensure that the USB device is securely
inserted and retry the operation.
2. Re-write the file to the USB device and retry
the operation.
3. Retry with another USB device.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
File Next Fail The library could not find
the next file in the USB
directory.
1. Ensure that the USB device is securely
inserted and retry the operation.
2. Re-write the directory to the USB device and
retry the operation.
3. Retry with another USB device.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
Table A-1 Library LCD error messages (continued)
Error Message Description Corrective Action