A-4
SCSI REFERENCE 1014826
CHAPTER A—ERROR CODES
Drive Empty The command cannot be
completed because the tape
drive does not contain a
cartridge.
Do one of the following:
Load a cartridge in the tape drive and retry the
operation.
If there are two tape drives installed in the
library, select a tape drive that contains a
cartridge and retry the operation.
Drive Full The command cannot be
completed because the tape
drive already contains a
cartridge.
Do one of the following:
Unload the data cartridge, then retry the
operation. See the Product Manual.
Wait until the current cartridge is unloaded by
the application, then retry the operation.
If the library contains two tape drives, retry the
operation on the second tape drive.
Drive Incompatible The detected tape drive is
incompatible with the
library.
Magnum 224, StorageLibrary T24, and
StorageLoader 2U LTO libraries are only
compatible with Ultrium 2 (LTO-2), Ultrium 3
(LTO-3), and Ultrium 4 (LTO-4) tape drives.
Magnum 448 libraries are only compatible with
Ultrium 2 (LTO-2) and Ultrium 3 (LTO-3) tape
drives. Ensure that you have one of these tape
drives installed in the library.
Drive Load Failed The cartridge couldn’t be
loaded into the tape drive
because of a mechanical
problem or because of a
broken tape.
1. Export the tape from the library (see the
Product Manual) and verify that it is in good
condition, then retry the operation. Replace
the cartridge if necessary.
2. If the error persists, contact Tandberg Data
Technical Support or your service provider.
Drive Timeout The tape drive took too long
to load or unload a tape, or
the tape drive is not
responding.
1. If possible, use the operator panel to
unloaded any cartridge that is in the tape
drive (see the Product Manual).
2. Power the library off and back on to reset the
tape drive.
3. If the error persists, contact Tandberg Data
Technical Support or your service provider.
Drive Unload Failed The cartridge couldn’t be
unloaded from the tape
drive because of a
mechanical problem.
1. Power the library off and back on to reset the
tape drive.
2. Retry the unload operation once.
3. If the error persists, contact Tandberg Data
Technical Support or your service provider.
Expired Cleaning Tape The cleaning tape in the
fixed cleaning slot has been
fully used.
Replace the cleaning cartridge with one that is
compatible with this tape drive. Use only LTO
cleaning cartridges with LTO tape drives.
Table A-1 Library LCD error messages (continued)