JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
10-9
WHAT THE LIBRARY RETURNS
I/E (Import/Export Element) – Byte 02, Bit 2
The value returned for this field indicates whether the library has an entry/exit
port that can store a data cartridge. The library does have an entry/exit port.
The valid value for this field is 1.
ST (Storage Element) – Byte 02, Bit 1
The value returned for this field is 1, which indicates that the cartridge storage
locations can store cartridges.
MT (Media Transport) – Byte 02, Bit 0
The value returned for this field is 0, which indicates that the cartridge loader
cannot store cartridges.
MT o DT – Byte 04, Bit 3
The value returned for this field is 0, which indicates that the library does not
support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is the tape drive.
MT o I/E – Byte 04, Bit 2
The value returned for this field is 0, which indicates that the library does not
support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is the entry/exit port element.
MT o ST – Byte 04, Bit 1
The value returned for this field is 0, which indicates that the library does not
support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is a cartridge storage location.
MT o MT – Byte 04, Bit 0
The value returned for this field is 0, which indicates that the library does not
support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is the cartridge loader.
ST o DT – Byte 05, Bit 3
The value returned for this field is 1, which indicates that the library supports
the MOVE MEDIUM (A5h) command when the source is a cartridge storage
location and the destination is a tape drive.
ST o I/E – Byte 05, Bit 2
The value returned for this field is 1, which indicates that the library supports
the MOVE MEDIUM (A5h) command when the source is a cartridge storage
location and the destination is the import/export element.
ST o ST – Byte 05, Bit 1
The value returned for this field is 1, which indicates that the library supports
the MOVE MEDIUM (A5h) command when the source is a cartridge storage
location and the destination is a cartridge storage location.