Quantum LTO 2U Instruções de Operação Página 219

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 264
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 218
JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
23-1
23
SEND VOLUME TAG (B6h)
23.1 ABOUT THIS COMMAND
The SEND VOLUME TAG command requests that the library scan the bar
code labels affixed to the cartridges and compare this volume tag information
with a template sent as part of a parameter list to this command. To obtain the
results of the scan performed by this command, use the REQUEST VOLUME
ELEMENT ADDRESS (B5h) command.
Bit
Byte
7 6 5 4 3 2 1 0
00 10110110
01 Reserved Element Type Code
02 (MSB)
Starting Element Address
(LSB)
03
04 Reserved
05 Reserved Send Action Code
06
Reserved
07
08 (MSB)
Parameter List Length
(LSB)
09
10 Reserved
11 00 Reserved 00