JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-3
ERROR MESSAGES DISPLAYED ON THE LCD
Busy The library is executing a
command issued from the
backup application when a
command is issued from the
operator panel.
Wait until the library has finished its current
operation, then retry the requested operation.
Cartridge Misloaded A cartridge was incorrectly
loaded into the library.
Reload the cartridge. See the Product Manual.
Circuit Failure The library has detected a
problem within its electronic
circuitry.
1. Power cycle the library.
2. If the error persists, contact Tandberg Data
Technical Support or your service provider.
Command Error The options for the
command were incorrect.
1. Verify that the options for the command are
valid. If they are not, correct the problem and
retry the command.
2. If they appear to be correct and the error
persists, contact Tandberg Data Technical
Support or your service provider.
Communication The library is unable to
communicate with the tape
drive.
Check the ADI interface cabling and
configuration. See the Product Manual.
Create File Fail See “File Create Fail” on page A-5
Device Not Ready The library is not ready to
perform the requested
operation because it is
performing diagnostics or its
power-on self-test (POST).
Wait until the library has finished, then retry the
operation.
Dir Create Fail The library could not create
a new directory on the USB
device.
1. Ensure that the USB device is securely
inserted and retry the operation.
2. Retry with another USB device.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
Disabled Sequential mode is not
enabled.
Sequential mode has been disabled during
execution of a sequential motion. Operator may
need to unload cartridges using the front panel.
See “Setting the Operation Mode” on page 3-1.
Drive Command A command issued from the
library to the tape drive
failed.
Check the ADI interface cabling and
configuration.
Verify that the tape drive is operating correctly.
See the Product Manual.
Drive Communication The library is unable to
communicate with the tape
drive.
Check the ADI interface cabling and
configuration. See the Product Manual.
Table A-1 Library LCD error messages (continued)
Error Message Description Corrective Action