JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
12-1
12
POSITION TO ELEMENT
(2Bh)
12.1 ABOUT THIS COMMAND
The POSITION TO ELEMENT command allows you to request that the
cartridge loader be positioned to a specific element location (address).
The cartridge loader is positioned so that no additional movement is required
to access the cartridge at that location for a MOVE MEDIUM (A5h) command.
Use this command with an application that may require a pause before issuing
a MOVE MEDIUM command. The time that you save with the POSITION TO
ELEMENT command is valuable if you would normally have to wait for the
cartridge loader to move to the element when you issue the MOVE MEDIUM
command.
Note: The average time required to complete this command is:
Magnum 224, T24, or SL 2U—10 seconds.
Magnum 448—15 seconds.
Bit
Byte
7 6 5 4 3 2 1 0
00 00101011
01 Reserved
02 (MSB)
Transport Element Address
(LSB)
03
04 (MSB)
Destination Element Address
(LSB)
05
06
Reserved
07
08 Reserved Invert
09 Reserved