JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
9-15
COMMAND STATUS
The command is issued to an invalid LUN.
A Unit Attention condition is pending for the initiator.
A reserved bit is set to 1 in the CDB.
The library detects an unrecoverable parity error while receiving the MODE
SELECT data.
A parameter in the CDB on a MODE SELECT page is invalid (see Ta b l e 9 - 3
for sense data).
Table 9-3 Invalid parameters in the MODE SELECT CDB and mode data
Sense
Key
ASC ASCQ
SKSV
Bit
C/D
Bit
BPV
Bit
Bit
Pointer
Field
Pointer
Error
5h 1Ah 00h 1 1 0 0 0004h Invalid Parameter List Length.
5h 21h 01h 1 0 0 0
a
Address overlap. The field pointer is set to
the value representing the field in the
Element Address Assignment page which
caused the address overlap, as follows:
0006h – Medium Transport Element
Address
000Ah – Storage Element Address
5h 24h 00h 1 1 1 A reserved bit is set in the CDB. The
pointers point to the bit in error.
5h 24h 00h 1 1 1 4h 0001h Invalid PF (page format). Must be 1.
5h 26h 00h 1 0 0 0
a
Invalid values in the Parameter List
Header. All values must be 0. The value of
the field pointer is the value of the first
field that contains a non-zero value (00,
01, 02, or 03)
5h 26h 00h 1 0 1 5h
a
Invalid Page Code.
5h 26h 00h 1 0 1 7h
a
Reserved bits set in the first byte of one of
the MODE SELECT pages.
5h 26h 00h 1 0 0 0
a
Invalid Parameter Length.
5h 26h 00h 1 0 0 0
a
Reserved bits set in the reserved fields 22
or 23 (bytes 18 or 19 of the Element
Address Assignment page).
5h 26h 00h 1 0 0 0
a
Invalid first import/export address.
5h 26h 00h 1 0 0 0
a
Storage element addresses are not
consecutive.
5h 26h 00h 1 0 0 0
a
Data transfer element addresses are not
consecutive.
Vista de página 110