Chapter 2 Installation Procedures
Installing the Internal LTO-4 (Model B) Half-Height Tape Drive
LTO-4 (Model B) Half-Height Tape Drive User’s Guide 9
2 Connecting the Internal Drive Interface and DC Power Cables on
page 13.
3 Restarting the Internal Tape Drive System
on page 15
4 Installing the LTO Driver Software
on page 23, if required.
5 Registering the LTO-4 (Model B) Half-Height Tape Drive
on page 23.
Configuring the
Internal Parallel SCSI
Ta p e Drive
The factory-set default configuration of the internal parallel SCSI LTO-4
(Model B) Half-Height Tape Drive is:
• SCSI ID: 6
• Terminator power: enabled
Configuring the Internal Drive Parallel SCSI ID
Each device on the parallel SCSI bus must have its own unique SCSI ID.
Use SCSI configuration jumper pins 1–2, 3–4, 5–6, and 7–8 on the drive
serial-attached SCSI (SAS), there is no need to configure the
SCSI ID or bus termination, as SAS
is a point-to-point architecture.
Skip to Mounting the Internal Tape
Drive on page 12
IF the drive interface is . . . THEN . . .
IF the default parallel SCSI
ID configuration is . . .
THEN you can . . .
compatible with your system
SCSI bus,
skip the following subsection and
proceed to Configuring the Internal
Parallel SCSI Terminator Power on
page 10.
already assigned to another
device,
change the configuration of either
the other device, or the LTO-4
(Model B) Half-Height Tape Drive, as
described in the following
subsection.
Comentários a estes Manuais