Vista de página 95
80
Chapter 6: Troubleshooting and Maintenance
If the rmware is already at the same level as the code on the tape, the DLT2000XT
tape drive does not go through the update process. If the rmware is not at the same
level as the code on the tape, the drive code goes through a two- to three-minute
update. During this time, the Write Protect and Tape in Use LEDs ash alternately.
After the drive code update is complete, the DLT2000XT tape drive resets and goes
through a POST, and the tape rewinds to the beginning-of-tape (BOT) marker. The
cartridge door should unlock and the green Operate Handle LED should turn on.
If the rmware image is valid, the controllers FLASH EEPROM memory is
automatically updated with the new rmware image. The Write Protect and Tape in
Use LEDs ash again during the controller rmware update.
At the end of the process, the drive unloads the rmware update tape. The green
Operate Handle LED comes on and the door unlocks.
6. Remove the rmware update tape.
If the rmware cartridge does not complete the actions listed in step 5, it means that the
update process has failed. The DLT2000XT tape drive may still be usable, but may
require service (depending on why the unit failed). The three most probable reasons for
a DLT2000XT tape drive failing to complete step 5 are
bad or corrupted data on the update tape cartridge
power cutoff to the DLT2000XT tape drive during the update process
•flash EEPROM malfunction
The rst two problems can probably be corrected fairly easily by obtaining a new update
tape or repeating the upgrade process. The third problem probably requires a qualied
service visit by a eld repair technician.
Updating Firmware on the DLT2500XT Stacker
Follow these steps:
1. Make sure tape operations are nished. For the rmware update to be successful,
the stacker must have passed the power-on self-test (POST).
2. With the LDR RDY message displaying press the Open button on the control panel
to open the door. Remove the magazine and close the door.
3. Remove all cartridges from the magazine; insert the code update cartridge into
slot 0.