Chapter 4 SCSI Interface
General SCSI Bus Operation
Quantum|ATL PowerStor L500 Series Tape Library Users Guide 65
The Test Unit Ready command is used to determine whether the
library would accept, for example, a Move Medium or a Position to
Element command without returning Check Condition status.
Bus Free
4
There are several situations when the device may go to Bus Free
unexpectedly, as defined in the SCSI-2 standard (see sections 4.1.1
and 4.3):
An internal hardware or firmware fault that makes it unsafe for
the device to continue operation without a full reset (similar to
a power-up reset)
ATN asserted or bus parity error detected during non-tape
data transfers
Bus Parity Errors
4
Bus parity errors (i.e. single bit errors) are very serious because
they imply the possibility of undetected double-bit errors on the
bus, which most likely would result in undetected data corruption.
On properly configured SCSI buses, parity errors should be
extremely rare. If any are detected, they should be addressed
quickly by improving the configuration of the SCSI bus. A well
configured SCSI system in a normal environment should be
virtually free of bus parity errors.
Bus parity errors cause the library to either retry the operation, go
to Status phase, or go to bus free and prepare Sense Data (see
section 6.1.1 in the SCSI-2 specification). Retrying of parity errors
during Data Out Phase when writing is normally not done, but can
be enabled by changing the EnaParErrRetry parameter in the VU
EEROM Mode Page. This feature is disabled by default due to
negative impacts on device performance (also, the data stream on
writes cannot be pipelined).