Quantum|ATL PowerStor L500 Series Tape Library User’s Guide 91
A7H Retry
command
Timed-out while opening the drives
handle during a LOAD CARTRIDGE
command.
A8H See
Description
Timed-out moving cartridge from the
CHM into the drive during a LOAD
CARTRIDGE command.
If this occurs as the only error, then this
error can be retried. The drive controller
must first unload the cartridge from the
drive. Then it can reissue the command.
If this error occurs as the second error
after either a 94H or an A9H error, then
this error is considered fatal.
A9H Retry
command
Timed-out while attempting to find
PUSHPOS 2 to push cartridge
completely into the drive during a
LOAD CARTRIDGE command.
AAH This code is not an error and will never
be returned in the status error bytes. It is
utilized in the error trace buffer as an
indicator every time a thousand cycles
has occurred.
ABH See
Description
Timed-out finding PUSHPOS 1 (rack
waiting position in front of the drive).
This error can be retried. The library
controller must first unload the cartridge
from the drive then, reissue the
command.
ACH Retry
command
Timed-out closing drive handle. This
error can occur during a LOAD
CARTRIDGE command or after error 94
if the loader controller tries to move the
cartridge back into the drive.
Error Code Error Type Description