Electromagnetic Interference (EMI) Susceptibility
70 Quantum|ATL PowerStor L200 Series Library User’s Guide
Conducted
Susceptibility
1
The transient voltage is the actual peak voltage above the normal
AC voltage from the power source.
The voltage limits for power and data cables are:
• 2 kV S/W recoverable errors
• No hardware failures
The power cable voltage limits are:
• 2.0 kV common mode (no errors allowed)
• 1.0 kV differential mode (S/W recoverable errors, no hardware
failure)
ESD Failure Level
Limits
1
This section lists the ESD failure level limits for normal operator
access areas.
Table 23 ESD Failure
Level Limits
Note: Maximum energy in a single pulse from the transient
generator must be limited to 2.5 W.
Failure
Type Equipment
Failure
Level Allowable Errors
Hardware Office to 12 kV No operator intervention (soft
recoverable errors allowed)
Hardware Office to 15 kV No component damage -
operator intervention allowed
(soft and hard errors allowed)