Diagnostics and Troubleshooting
ValueLoader Error Codes
ValueLoader DLT VS80/DLT VS160 Tape Autoloader User Manual 59
30A3
Cartridge Pick Error. An error occurred while trying to pull a
cartridge from the drive or a carousel slot.
30A4
Import/Export Slot Position
Error.
The Import/Export slot door was not in the
requested position during device operation.
Can be caused by manually opening the door
or a cartridge or other obstruction is blocking
the door. Try removing the cartridge or
obstruction, then power cycle or reset the
ValueLoader.
30A5
Fan Error. The ValueLoader processor detected a fan
error.
30B0
ROM Error. Power cycle the ValueLoader and attempt the
operation again. If the error recurs, contact
Quantum Technical Support.
30B1
RAM Error. Power cycle the ValueLoader and attempt the
operation again. If the error recurs, contact
Quantum Technical Support.
30B2
NVRAM Error. Power cycle the ValueLoader and attempt the
operation again. If the error recurs, contact
Quantum Technical Support.
30B3
Controller Timer Failure. An unrecoverable failure has occurred in the
controller timer circuit.
30B4
Loader to Drive
Communication IC Error.
A failure in IC handling loader to drive
communication.
30B5
Display Error. Power cycle the ValueLoader and attempt the
operation again. If the error recurs, contact
Quantum Technical Support.
30B6
Memory Error. Power cycle the ValueLoader and attempt the
operation again. If the error recurs, contact
Quantum Technical Support.
Error Code Description Details