SCSI Commands
Quantum DLT 4000 Tape Drive 5-47
LOG SENSE Command (4Dh) (continued)
Table 5–21 Log Parameters for Read / Write Error LOG SENSE Page Field Descriptions
(continued)
Field Name Description
TMC (cont.) The criteria for comparison are:
Code - Basis of Comparison
00b - Every update of the cumulative value
01b - Cumulative value equal to threshold value
10b - Cumulative value not equal to threshold value
11b - Cumulative value greater than threshold value
LP List Parameter. This bit is 0 since the parameter codes are treated as data counters.
Parameter
Length
This field specifies the number of bytes of the parameter value.
Parameter
Value
This field indicates the actual value of this log parameter.
5.8.4 Last n Error Events Page (07h)
This page returns one parameter at a time that contains the ASCII text for the
specified event log. The Parameter Number field in the CDB specifies the log
event to return. The log events in EEPROM are numbered from 0 to 255, after
which the number wraps back to 0; only a limited number of events are stored at
a given time (up to 14). The log event that is returned is the one whose
Parameter Code is equal to, or the first one greater than, the Parameter Number
specified in the command control block.