Quantum ValueLoader Manual do Utilizador Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 71
Diagnostics and Troubleshooting
ValueLoader Error Codes
58 ValueLoader DLT VS80/DLT VS160 Tape Autoloader User Manual
308F
Recovered Loader Error. Loader error recovery successful. Your
diagnostic tool can provide details of the
original loader error.
3090
Mechanical Initialization
Failure.
The robotics were not able to move to the safe
mechanical initialization position. Manual
intervention is necessary.
3091
Inventory Scan Failure. Fatal robotic error occurred during the
inventory scan.
3092
Preposition Failed. Belt positioning error occurred during
Preposition command.
3093
Cartridge Load Error. A failure occurred while trying to load a
cartridge from a slot to the drive.
3094
Cartridge Unload Error. A failure occurred while trying to unload a
cartridge from the drive to its slot.
3095
Import Error. An error occurred while trying to import a data
cartridge to a carousel slot.
3096
Export Error. An error occurred while trying to export a data
cartridge from its carousel slot. This can be
caused by an empty slot that is expected to be
full.
30A0
Carousel Motion Failure. An error occurred during carousel movement
(position not found). Could be caused by a
missing or misaligned cartridge carrier, an
obstruction, or unexpected cartridge in either
the carousel path or import/export slot.
30A1
Cartridge Transport Position
Error.
The cartridge transport element is unable to
reach its desired position. Failure occurred
while trying to place a cartridge into or remove
a cartridge from the drive or a slot.
30A2
Gripper Position Error. Gripper unable to reach position.
Error Code Description Details