11-84 6-00667-01 Rev B
Scalar 100
4. Click Submit and review your changes (indicated in red).
5. Enter your password and click Confirm to complete the procedure.
Configuring the Time and Date
You can configure the date and time for the RMU. The date and time will be used in the RMU log
file to report when events occurred.
To configure the date and time
1. Click the Configuration tab.
2. Enter the date and time in the Date and Time area.
3. Click Submit and review your changes (indicated in red).
4. Enter your password and click Confirm to complete the procedure.
Synchronizing with an NTP server
You can connect the RMU to a network time (NTP) server to automatically set the time.
To synchronize with an NTP server
1. Click the Configuration tab.
2. In the Date and Time area, select ON from the Sychronization with NTP server drop-down
menu.
3. In the NTP Server IP Address field, enter the IP address of the NTP server.
4. In the Timezone field, enter the time zone deviation for the NTP server. To get a list of timezone
variants, click list of timezones.
5. Click Submit and review your changes (indicated in red).
6. Enter your password and click Confirm to complete the procedure.
Updating Firmware
You can update firmware for the RMU, library, and drives (LTO only). Before you update firmware,
you need to have the firmware file in a location that is accessible from the RMU interface. Firmware
updates can be found on www.adic.com
.
To update firmware
1. Click the Firmware tab.
2. Select the firmware you would like to update.
NOTE:
Only LTO drive firmware can be updated with the RMU.