Chapter 4 Using Your Tape Drive
Power-On Self-Test
SDLT 600 Product Manual
Power-On Self-Test 4
The SDLT 600 tape drive system performs a Power-On Self-Test (POST)
each time the tape drive is powered on. POST normally completes in 10 to
15 seconds—when a data cartridge is not in the tape drive— when the
unit is powered on. However, if a data cartridge is in the tape drive when
the unit is powered on, POST duration is longer, depending on how
much tape in the data cartridge may be loaded in the tape drive.
While POST is running, the SDLT 600 tape drive system responds BUSY
to SCSI commands. The SDLT 600 tape drive system also responds to
various SCSI messages during POST.
During this time, if a host tries to negotiate Synchronous or Wide
transfers, the SDLT 600 tape drive system negotiates to Asynchronous or
Narrow. It may take longer than the duration of POST for the tape drive
to become ready.
Table 31
provides the sequence of operation to expect when power is
turned on. See figure 19
to help familiarize yourself with the LEDs on the
front panel.
Table 31 LED Lighting Pattern
During Power-On Self-Test
(POST)
Stage What You Observe
1 (Power
On)
All LEDs illuminate for approximately one second.
2 The LEDs flash on, then off in a progressing pattern from
left to right. Stages 1 and 2 generally complete within
approximately five seconds.
3 The right LEDs remain off, the left LED illuminates
steadily, and the middle LED flashes until POST
completes. This stage typically lasts for 5 to 10 seconds.
4 When POST is complete, the middle LED stops flashing
and remains illuminated; the left LED turns off, and right
LED remains off.
POST
Failure
If POST fails, the middle and right LEDs illuminate
steadily and the left LED flashes.