Quantum PX502 Guia do Utilizador Página 175

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 174
Chapter 4 SNMP Trap List
Quantum PX500 Series User’s Guide 152
Codeupdate failed
(status)
A code update has failed. Informational Code update
Backplane nv erase err
(region id/status)
Non Volatile memory on the back
plane could not be erased.
Replace the backplane to restore
normal library operations.
Critical Diagnostics
Backplane nv read err
(region id/status)
Non Volatile memory on the back
plane could not be read. Replace
the backplane to restore normal
library operations.
Critical Diagnostics
Backplane nv write err
(region id/status)
Non Volatile memory on the back
plane could not be written.
Replace the backplane to restore
normal library operations.
Critical Diagnostics
Hand-camera image fail The camera in the robotics hand
has failed to read an image.
Critical Diagnostics
Hand-camera init fail The camera in the robotics hand
has failed its initialization routine.
Critical Diagnostics
Selftest Camera FIFO
failure
The camera in the robotics hand
has failed to read its memory used
to transfer data.
Critical Diagnostics
Selftest display bram
failure
The diagnostic buffer used to
report test results is not large
enough to hold the data.
Critical Diagnostics
Scb-fpga camera fifo fail The memory on the system
controller board has failed to read
the memory used to transfer data.
Critical Diagnostics
Test details buffer
overflow (len/testId)
The diagnostic buffer used to
report test results is not large
enough to hold the data.
Critical Diagnostics
Test record semaphore
locked (index/tx-status)
An internal firmware error has
occurred.
Critical Diagnostics
Event Detail Event Description Category Reported By