MODE SENSE (6) / (10) Command (1Ah / 5Ah) SDLT 600 SCSI Interface Guide
4-116 January 2005 81-81200-02 REV A01
Disconnect / Reconnect Page (02h)
The drive supports the Disconnect / Reconnect Page. The format for the page is shown in the following
figure.
Figure 4-65. Disconnect / Reconnect MODE SENSE Page — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 PS (0) SPF (0) Page Code (02h)
1 Page Length (0Eh)
2 Buffer Full Ratio (0)
3 Buffer Empty Ratio (0)
4 – 5
(MSB)
Bus Inactivity Limit (0)
(LSB)
6 – 7
(MSB)
Disconnect Time Limit (0)
(LSB)
8 – 9
(MSB)
Connect Time Limit (0)
(LSB)
10 – 11
(MSB)
Maximum Burst Size (0)
(LSB)
12 EMDP Fair Arbitration DIMM DTDC
13 Reserved
14 – 15
(MSB)
Reserved
(LSB)