MODE SELECT (6) / (10) Command (15h / 55h) SDLT 600 SCSI Interface Guide
4-70 January 2005 81-81200-02 REV A01
Figure 4-40. MODE SELECT (10) Mode Parameter List — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 – 7 Mode Parameter Header
8 – 15 Mode Parameter Block Descriptor (Optional)
8 – n
or
16 – n
Page(s) (Optional)
Table 4-43. MODE SELECT Mode Parameter List — Field Descriptions
Field Name Description
Mode Parameter
Header
Four bytes in length for MODE SELECT (6) or 8 bytes in length for
MODE SELECT (10). Contains information about the remainder of the
Parameter List and is always present.
Mode Parameter
Block Descriptor
Eight bytes in length. Allows the host to set the drive’s Logical Block
Size and Density Code to be written from BOT.
Page(s) The Page Code or Codes of the pages that are a part of this MODE
SELECT command.