Vista de página 18
Addressed Tickets 17
AMU
Addressed Tickets
The addressed tickets and issues are described in this section.
AMU 3.11
AMU 3.10
The AMU 3.10 tickets are listed below.
Version 3.10E
Ticket number Problem
ET31428
CR12218
Eject to 'unknown' position (not scanned by Auto-Invt). This ticket was
announced as fixed in AMU 3.10E but was actually fixed in AMU 3.11. The
problem was related with eject commands to EIF unit with Auto-Inventory
command running. Under this condition (not all I/O slots were scanned)
AMU can produce the error “Source position is unknown.”
DCI communication problem with port 1
CR12209 Database update problem for flip and move to the problem box
Cleaning fails in case of KEEP error
Asynchronous clean request fails during high workload
DBBACKUP killed the system if drive is read-only
CR12220 BUD time settings and communication failures
NetOp – cannot enter in drive configuration dialog (in GUI configuration)
‘Hanged’ KEEPs
Ticket number Problem
ET43401 Help button of ConLog has no function
The Help button of ConLog will display the help information about ConLog.
ET60326 Scratch volumes are possible in more then one pool
The AMU will check the presence of a given volser in other pools and
prevent the user from entering it in another pool.This problem has not been
resolved
ET70065 Problems with disaster recovery
There was a problem with disaster recovery -- 10th cartridge in recover list
was moved to the position of the first one.This problem has not been
resolved