12 6-00344-03
AMU
Version 3.10B
KrnPmac.dll fixed problem with PMAC register dump
Build answer for correct command with correct return code. Avoid blocking of
KrnP when first command is to a DG drive and it fails. Remember PIDDATA for
command if there is an error in KrnReadAMUPQueue called from
KrnSendContMsg. Build answer for failed command if KrnSendContMsg fails,
not for command that triggered this function. New function
KrnTriggerResponseAndCommand that replaces the calls of
KrnBuildAMUPResponse. This function triggers the next RHO command by
KrnSendContMsg and handles its errors. It also builds the answer for the
requested command by calling KrnBuildAMUPResponse.
Log.dll Trace messages added (especially for LogInitReadForce), length for strcmp
corrected, so the name of the monitoring queue should be found during the
second run. Length for EvtSend of the name of the new monitoring queue
corrected (sending the zeroterminated string).
LogView.exe After use of push button 'View,' the correct tool (Log2Asc.exe or LogCopy.exe)
is used to generate the logview.txt. The choice is done by the filename of the
selected file (starting with log* indicates the use of Log2Asc). This is an
additional feature for more convenience.
Rte.exe Rte should only work on commands with a minimum of 70 characters, AML/2
format has 70 characters, usable ABBA1 format has 80 characters. On shorter
commands there is the risk of an access violation.
Module Description
KrnPmac.DLL Changes in the synchronization of the threads (Problems with fast > 300MHz
Computers). Initialization of variables with 0.
Changes in the memory management.
Bud.exe • Changes in the Log- and Traces for better analysis for the problem of a lost
of communication between the two AMU computers.
• Additional changes in the memory management.
Clm.exe If the user increased the MaxUseCount of a drive when cleaning had started
(already sent NTFY 1309) the clm now completed this cleaning to prevent a
permanently locked drive.
FileTr.exe GUI fields can now be entered by the Tab key.
AmuConst.ini
AmuConst.rc
ADS icon was missing because a value DTYP NUMOF was not correct.
ConArc.DLL Check boxes now only enabled for devices from tower type
ConEdVol.DLL For Update all in Edit Volser Range, now the field Owner must be filled with
values 1-3.
ArcBase.DLL Additional check of the COwner, modification only to 1,2 or 3 allowed.
Table 11 Changes in the modules for version 3.10C
Module Explanation of Changes