4-96 Menus and Commands
6-00058-05 Rev A
Drives Dialog
Path: Main Menu Setup Cleaning Drives
Use the Drives Dialog to select automatic, or scheduled
(specifying a time) for cleaning your drives. See Figure 4-135.
Figure 4-135 Drives Dialog
Parameters Description
AutoClean Y to enable automatic drive
cleaning
N to reject automatic drive
cleaning
Schedule Immediate to allow drive
cleaning when requested by
the drive
Delayed to schedule drive
cleaning for requesting drives
at the specified time
Hours Hour (00–23) that cleaning
should start
Min Minute (0–59) that cleaning
should start
Accept Y to accept changes
N to reject changes
If Y is selected, the screen updates to reflect the changes.
Otherwise, the changed parameters continue to display
but no action is taken.
AutoClean:Y<
Schedule: Delayed
Hours: 00Min :00
Accept:: N