Quantum Scalar i2000 Guia do Utilizador Página 422

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 421
The library automatically performs an inventory
after it completes the configuration teach process.
Chapter 6 Maintaining Your Library
Maintenance Actions
Scalar i6000 User’s Guide 409
1 Log on as an administrator.
2 Ma
ke sure that you are viewing the physical library. From the View
menu, click the name of the physical library.
3 Click Tool
s > Teach.
The Teach dialog box appears.
Configure is already selected by default.
4 Click St
art.
During the configuration teach process, the picker moves to each
storage magaz
ine, I/E magazine, and drive in the library and stores
information about them. Teach results appear in the Results text box
when the process completes. If the configuration teach process
completes successfully, the Teach dialog box could close
automatically.
Note
If the physical library is not offline, you receive a
message that asks you whether you want to take it
offline. Click Yes.