Quantum P2000 Guia do Utilizador Página 56

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 146
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 55
Chapter 2 Basic Library Operations
Changing the Touch Screen GUI Security Levels
36 ATL P2000 Series Automated Tape Library Users Guide
Table 6 Security
Levels (listed from
highest to lowest)
Securing the Touch
Screen GUI
2
When the User security level is set, access is restricted to the
Operator and Service screens. Since these screens control library
configuration, testing, and initializing functions, the User security
level is appropriate default condition for routine library operation.
Changing Security Levels
2
To change security levels:
1
Press the Lock icon.
The Password screen appears (see figure 21
).
2
Press the desired security level button (Service, Operator, User,
Import Only, or Locked).
Level
Lock
Icon
Indicator
Password
Protected
Overview
Screen
Access
Tapes
Screen
Access
Operator
Screen
Access
Service
Screen
Access
Load
Port
Access
Stop and
Standby
Access
Service S Yes Yes Yes Yes Yes Yes Yes
Operator O Yes Yes Yes Yes No Yes Yes
User U Yes Yes Yes No No Yes Yes
Multi-Unit O Yes No No No No No No
Import
Only
I Yes Yes Yes No No Yes No
Locked L No Yes Yes No No No No
Vista de página 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 145 146

Comentários a estes Manuais

Sem comentários