Quantum Scalar i2000 Guia do Utilizador Página 38

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 77
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 37
Chapter 3 System Specifications
Electrical Specifications
Scalar i2000 Planning Guide 34
Table 5 Scalar i2000 Power
Consumption Characteristics
230V / 50 Hz / 1 pH.
Robot Operating
Total Number Drives 12 12 12 12 6 3 1 0
Operational Drives 12 6 3 1 6 3 1 0
KW 0.77 0.76 0.75 0.74 0.54 0.48 0.35 0.31
KVA 0.82 0.8 0.79 0.79 0.58 0.52 0.38 0.35
KVAR (capacitive) 0.28 0.26 0.26 0.26 0.22 0.21 0.16 0.16
Power Factor 0.94 0.94 0.94 0.95 0.93 0.92 0.9 0.89
Crest Factor 1.85 1.85 1.82 1.82 1.87 1.8 1.68 1.6
Amps (RMS) 3.63 3.54 3.53 3.55 2.58 2.15 1.85 1.6
Amps (Peak) 7.097 7.214 7.063 6.983 5.532 4.714 3.924 2.588
208 v / 60 Hz / 1 pH.
Robot Operating
Total Number Drives 12 12 12 12 6 3 1 0
Operational Drive 12 6 3 1 6 3 1 0
KW 0.77 0.76 0.76 0.75 0.54 0.43 0.35 0.31
KVA 0.82 0.81 0.8 0.8 0.57 0.46 0.38 0.34
KVAR (capacitive) 0.28 0.27 0.27 0.27 0.18 0.17 0.15 0.14
Power Factor 0.94 0.94 0.94 0.94 0.95 0.93 0.92 0.91
Crest Factor 1.68 1.69 1.7 1.7 1.69 1.61 1.56 1.58
Amps (RMS) 4.06 3.92 4.04 3.91 2.78 2.31 1.93 1.75
Amps (Peak) 7.227 7.244 7.078 7.122 7.045 4.422 3.975 2.787
Vista de página 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 76 77

Comentários a estes Manuais

Sem comentários