6 Sun StorEdge DLT8000 Tape Drive Installation and User’s Guide • February 2001
Troubleshooting
If the tape drive fails during POST or operation, use Table 1-1 to identify the
problem and determine what action to take.
TABLE 1-1 Troubleshooting
Symptom: Your system does not recognize the DLT8000 tape drive.
Action:
Make sure that:
• The SCSI ID is unique.
• The SCSI cable is not loose.
• The SCSI bus is correctly terminated.
• You have rebooted the system using the boot -r command.
Symptom: All LEDs on the right or left side of the tape drive front panel blink.
Action:
Unload the tape and reinitialize the drive by pressing the Unload
button, or power off the tape drive, wait 15 seconds, and then
power it on again. The right or left side LEDs should stop blinking,
and the drive should try to reinitialize. If the test succeeds, the
LEDs should turn on steady, and then turn off.
If all right or left side LEDs continue blinking, the drive has a
hardware failure.