Chapter 3 OpenView NNM on Solaris
Duplicate IP Addresses
28 SNMP Integration Guide
Duplicate IP Addresses 3
As a final step in the SNMP integration with HP OpenView NNM, an
entry needs to be added the HP OpenView nodiscover file. This entry is
necessary to ensure that the IP address of the second Ethernet port on the
PMC is not detected as a duplicate IP address when more than one PMC
is attached to a network. Before powering on the library containing the
PMC, perform the duplicate IP addresses procedure.
To create duplicate IP addresses:
1 Determine the IP address of the PMC Ethernet port.
If the IP address of the PMC Ethernet port attached to the network
begins with anything other than the number 10, the IP address of the
second port is
10.0.0.254. Otherwise, the IP address of the second
Ethernet port is
192.168.0.254.
2 Create an ASCII file. Name and place it as follows:
$OV_CONF/netmon.noDiscover
3 Add a line to the file containing only the IP address determined in
step 1
of this section.
For example, if the IP address of the second Ethernet port is
determined to be
10.0.0.254, then add the following line to the file:
10.0.0.254 #MC300 private network address.
Setting Up OpenView NNM 3
After the SNMP integration software is installed, set up OpenView NNM.
To set up OpenView NNM:
1 If OpenView NNM is running, shutdown and restart OpenView
NNM.
If OpenView NNM is not running, start OpenView NNM. To run
OpenView NNM, type:
#opt/OV/bin/ovstart
#opt/OV/bin/ovw