Quantum DAT 160 Guia do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 18
Chapter 1 Introduction
LED Action Sequences
Quantum DAT 160 User’s Guide 5
Ready is ON.
The drive is ready for
operation.
None. This is normal.
Ready FLASHES.
The drive is carrying out a
normal activity (read, write).
None.
If the drive is upgrading firmware, do not reset or
power cycle it.
Clean FLASHES.
The drive requires cleaning. Load the cleaning cartridge.
If the Clean LED is still flashing when you load a
new or known good data cartridge after cleaning,
call for service.
Ready FLASHES and
Clean is ON.
Cleaning is in progress. None. The cleaning cartridge will eject on completion.
The cleaning cycle can take up to 5 minutes to
complete.
Tape FLASHES.
The drive believes the current
tape or the tape just ejected is
faulty.
Unload the tape cartridge. Make sure that you are using
the correct format cartridge.
Reload the cartridge. If the Tape LED still flashes or
starts flashing during the next backup, load a new or
known good cartridge.
If the Tape LED is now off, discard the 'suspect' tape
cartridge. If it is still on, call for service.
Drive FLASHES.
The drive mechanism has
detected an error.
Load a new cartridge. If the error persists, power cycle
or reset the drive.
If the Drive LED remains on, call for service.
Drive, Tape and Ready
FLASH.
There is a firmware download
problem.
Insert a cartridge to clear the LED sequence. If the
condition persists, call for service.
LED Sequence Cause Action required